Difficulty: Easy
Correct Answer: Chassis ground
Explanation:
Introduction / Context:Electrostatic discharge (ESD) control is critical when servicing computer hardware. A conductive workbench surface, wrist strap, and proper grounding prevent damaging voltage spikes from building on you or the equipment. Choosing the best ground reference ensures charge equalization happens safely and predictably.
Given Data / Assumptions:
Concept / Approach:
The ESD benchmark is to reference all items (technician, bench, and device-under-test) to the same electrical potential—usually the equipment chassis which is bonded to a verified protective earth. Chassis ground (earth-referenced) keeps the device and the work surface at the same potential, minimizing ESD events.
Step-by-Step Solution:
Identify that an ESD-safe setup uses one common point ground (CPG).Connect the bench ESD mat and wrist strap to chassis ground that is earth-bonded.Verify ground with an ESD tester or continuity check to protective earth.Work only when your strap and bench show proper resistance to ground (typically 1 MΩ series resistor for safety).Verification / Alternative check:
Most ESD standards and service manuals recommend a common point connected to equipment chassis ground which is bonded to building safety earth. This provides a safe, low-impedance return while limiting fault current via series resistance in straps.
Why Other Options Are Wrong:
Common Pitfalls:
Final Answer:
Chassis ground.